Bell Equipment
Bell Communications Card |
Emergency Diver Recovery Hoist |
Bell Battery Housing |
Model No: BCC |
Model No: BHS |
Model No: HD Series |
![]() |
![]() |
|
Description: |
Description: |
Description: |
| A bell emergency communications card depicting the knocking codes applicable for communications between the crew of a lost bell and the rescue team. This would typically be installed on the inside and outside of the bell. | The hoist is typically used in the emergency recovery of a diver into the bell. The hoist assembly includes a 10mm rope on a triple block pulley. The system comes complete with an adjustable pulley, bow shackle and spring snap hook. The product is assembled and tested in our factory and issued with a certificate of test. The rope length can be cut to suit your requirements. | It is big, but designed to fit into the 50 Litre cylinder bracket space. It can easily supply power for many of today’s modern bell requirements and is fitted with shunt protection, reverse polarity and short circuit diode protection. |
Specifications: |
Specifications: |
Specifications: |
| Width x Height: 150mm x 110mm | Length, Thickness: 30m, 10mm SWL: 200kg |
Length, Diam: 1792mm, 256mm Maximum External Depth Rating: 300MSW Temperature Range: 0 °C - 52 °C Relief Valve Discharge Pressure: 0.3 bar Voltage Supply: 220/110VAC Voltage Output: 24VDC Capacity: 75Amp Hours Charger: 10Amp |
Umbilical Cutter |
Oil Filled Junction Box |
Bell Hot Stab Unit - External ROV Plug |
Model No: UC94/108 |
Model No: OB 780 x 380 |
Model No: ROV-EG |
![]() |
![]() |
![]() |
Description: |
Description: |
Description: |
| The umbilical cutter is an emergency device used to sever the umbilical. It consists of a blade, in a Stainless Steel housing, which is actuated from within the bell by means of a hydraulic hand-pump. It is designed to easily cut through a fully pressurized umbilical fitted with a Kellems grip. All controls are mounted inside the bell. The umbilical cutter is fitted with a safety pin designed to resist an 80 bar back-pressure on the hydraulic system. This ensures that should any water or gas pressure be trapped in the hydraulic system, the umbilical will not be inadvertently cut. | The oil-filled junction box is an A316 Stainless Steel box, with a Polycarbonate cover. It houses all the electrical connections from the main umbilical, and splits it to the different communications, lights, equipment, etc. It is equipped with an oil pressure compensator, a drain valve located at the bottom, and a pressure relief valve. | In the event of a bell separation from the main system, the occupants will have a limited amount of electricity, gas and heat available to sustain them. The hot stab unit is an emergency device installed on the side of the bell that allows the interfacing of a secondary / emergency umbilical cord to the bell, thus maintaining life support while a rescue is underway. The unit has 2 modules, one for electric interfacing and the other for liquids and gases. During normal operation, the units on the bell are fitted with blanking plugs which seal off the system. An emergency umbilical cord with interfacing plugs is attached to a ROV (remote operated vehicle) and sent down to the separated bell. The ROV operator then unplugs the blanks and inserts the umbilical. |
Specifications: |
Specifications: |
Specifications: |
| Diameter: 94 - 108mm Temperature Range: 0 °C - 52 °C Max Working Pressure: 310 bar Umbilical Type: Cortland Fibron Kellems Grip Type: To suit umbilical spec |
Inner Length x Width x Height: 690mm x 295mm x 155mm Outside Length x Width x Height: 780mm x 380mm x 180 mm Man External Pressure Differential: 3 bar |
Hot Water Port: 1/2 inch NPT Gas Supply Port: 1/2 inch NPT & 1/4 inch NPT Electric Supply: power & audio |
Carbon Dioxide Scrubber |
Bell Heater |
|
Model No: Hydra 500 |
Model No: Hydra 501 |
|
![]() |
![]() |
|
Description: |
Description: |
|
| The Hydra 500 carbon dioxide scrubber is the scrubber of choice for air and saturation systems. With a high reliability and simple design, the Hydra 500 gives you a neat, easily cleanable and compact scrubber. The size enables it to fit through most medical locks and equipment locks. | Looking for bell heating / cooling options? The Hydra 501 bell heater is a reliable and inexpensive solution. | |
Specifications: |
Specifications: |
|
| Length x Width x Height: +/- 260mm x 250mm x 270mm Weight: +/- 5.2kg Operating Depth: up to 300 MSW Gas Flow: 420 Litres / min (actual) Canister Capacity: 4.5 Litres Power Requirements: 12 / 24VDC (current draw = 1Amp at depth) Electrical Connector: MCIL3F Locking Sleeves: DLSA-F |
Length x Width x Height: +/- 520mm x 310mm x 280mm Weight: +/- 12.7kg Operating Depth: up to 300 MSW Gas Flow: 420 Litres / min (actual) Heating Capacity: 2.5kW Power Requirements: 12 / 24VDC (current draw = 1Amp at surface) Electrical Connector: MCIL3F Locking Sleeves: DLSA-F Connection Size: 3/4 inch NPT female fitting |
|