Analox CO Monitors
Model No: 3000 SeriesDescription:The Analox 3000 Analyser is recommended for use with air diving systems and SAT diving, for monitoring the CO content in the gas supplied to the diver. The sensor can be mounted remotely from the 3000 display panel. The Analox 3000 may also be used in the compressor room on a ship. Calibration is quick and easy using the adjustments on the front panel. It has adjustable hi and low audio and visual alarms. Options are available for relay, 4-20mA outputs and battery back-up. The device is designed to be user serviced and maintained with minimal user downtime and is also recognisable world-wide by the majority of diving technicians, making it easy to use. It accepts all known power voltages world-wide and is available in panel mount or rack mount.
|
![]() |
Analox CO2 Monitors
Model No: 5001 SeriesDescription:The Analox 5001 Series Monitor is manufactured specifically for the hyperbaric and commercial diving industries. The Analox 5001 is located in the dive control room, at ambient temperature and pressure. When supplied with a gas sample line from the living chamber, diving bell or gas reclaim system the Analox 5001 will provide carbon dioxide readings in parts per million. The device features temperature and drift compensation. Calibration is quick and easy using the adjustments on the front panel. It has adjustable hi and low audio and visual alarms. It accepts all known power voltages world-wide and is available in panel mount or rack mount. |
![]() |
||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||
Analox Hydrocarbon/He/O2 Monitor
Model No: Hyper-Gas MkIIDescription:Analox Hyper-Gas MkII is a purpose-designed hydrocarbon gas analyser for use in hyperbaric environments. It has been designed to detect and warn divers of anaesthetic levels of hydrocarbons in the bell atmosphere. Inside the bell, the monitor will rapidly detect the presence of vapourised hydrocarbons, and will activate the audible and visual alarms before the anaesthetic threshold is reached. The analyser is designed to operate to depths of up to 587m (1926ft.) and automatically corrects pressure and temperature effects ensuring optimum performance in this difficult environment. The gas alarm level is preset to 10% of the anaesthetic dose of vapourised hydrocarbons that could be present in the diving bell. For diving in areas where contamination is known to be 1 or 2 compounds, an alternative alarm set point could be calculated by Analox. The internal sample pump ensures a fast response to hydrocarbons. An optional topside repeater mounted at the surface mimics the conditions inside the bell. |
![]() |
||||||||||||||||
|
|||||||||||||||||
Analox O2 Monitor
Model No: 1000 SeriesDescription:The Analox 1000 Series Analyser is specifically designed for the saturation diving market. As a result these analysers have a familiarity and intuitive operation to suit deep diving shift patterns. The Analox 1000 Oxygen Monitor is located in the dive control room at ambient temperature and pressure. When supplied with a gas sample line from the living chamber, diving bell or gas delivery system, the Analox 1000 Oxygen Monitor can be configured to provide percent oxygen readings (%O2 ). Calibration is quick and easy using the adjustments on the front panel. The device is designed to be user serviced and maintained with minimal user downtime and is also recognisable world-wide by the majority of diving technicians, making it easy to use. In the event of interrupted power supply, a battery back-up option is available. Common fixings and connections enables quick installation. The device is supplied with a range of different sensor types. |
![]() |
Specification: |
|
| Length x Width x Height: | 107mm x 245mm x 129mm |
| Temperature Effect | ±0.1% of readout per °C |
| Operating Temperature | 0 - 60 °C |
| Storage Temperature | -40 - 85 °C |
| Relative Humidity | 95% at 40 °C non-condensing |
| Range | 0.01 - 100.00% at atmospheric pressure or 0 - 2000m bar pp |
| Internal Battery Back-up (optional) | 5V 1.4 AH Nickel Cadmium, back-up time ±1 hour min |
| Alarm Relay Outputs | 2 x Single pole change-over 1 Form A (15A 120VAC/24VDC), 1 Form C (10A 120VAC/24VDC) Configurable to be energised or de-energised when in non-alarm condition |
| Alarms | 2 x Audio/visual alarms, configurable as HI/HI or HI/LO. Alarms fully adjustable over FS range of instrument. |
| Analogue Outputs | 0-1V over FS range, 4-20mA over FS range |
| Display | 4 - 1/2 inch digital red LED |
| Power Supply Options | AC input 85V-264V, DC input 12V-32V, Input frequency 47-63Hz 6 Watts max power |
HYDRA O2 Analyser
Model No: MK IIDescription:The HYDRA O2 Analyser (MK II) is a portable battery-powered device for measuring oxygen concentrations in breathable gas mixtures; supplied with alarms, fuel cell, certificate and manual. It can be used in a variety of applications such as medical and industrial environments.
|
![]() |
Air Purity Test Kit
Model No: AP 201Description:An inexpensive air analysis kit used to test the purity of breathing air from a compressor or breathing air cylinders. Tests for hazardous levels of: Carbon Monoxide, Carbon Dioxide, Water Vapour, and Oil Mist. The kit consists of a waterproof Pelican case, pressure regulator, flow-meter, various adaptors, and tubing.
|
![]() |