Model no: Mixmaster HP
Description:
The Nitrox membrane must be supplied with a clean low pressure air supply; this can either come from a high pressure breathing air storage (in combination with a Mixmaster HP) or from a low pressure air compressor with excellent purification before the membrane (in combination with a Mixmaster LP). Available in Large and Small. The Mixmaster HP panels have an HP breathing air inlet with isolation valve and pressure reducer that safely reduces the HP supply down to the desired LP inlet pressure. The Mixmaster HP panels have a large capacity active charcoal filter to ensure no oil enters the membrane. The HP solution has the advantage of using pure breathing air to feed the membrane; this reduces the risk of membrane contamination.
Specifications:
Depth x Width x Height: 300mm x 650mm x 1150mm Weight: 75kg Inlet Pressure: 50 > 350 bar (G 1/4 inch female) Membrane Inlet Pressure LP: 4 > 11 bar (11.5 bar safety valve) Outlet to Compressor (Air/Nitrox): G 1 inch female Air Inlet (for Filling operations): G 1 inch female |
|
 |