Hydra | Products: Environmental Control Systems
Image of pressure chamber

 

External Chamber Regeneration System

External Chamber Regeneration SystemTitle: External Chamber Regeneration System
Model No: ERS 300

Description:

  • The external gas regeneration system is designed to circulate gas from inside the chamber system and remove high levels of CO2, humidity and correct the temperatures to preset parameters required by the controller.
  • Carbon Dioxide is removed by usingchemical absorption techniques. Humidity in removed by condensation of the water vapour and heating or cooling of the gas applied to provide the optimum environmental temperature for the occupants.
  • General Construction
    • Complete stainless steel frame construction.
    • Open design for ease of access and maintenance.
    • Manual condensate valves provided for draining of condensate.
    • All refrigeration piping lagged and protected.
  • Remote controls
    • Temperature & humidity control display - remotely situated at SAT control
  • Heating system
    • 18 kW electrical elements are supplied to heat up a glycol mix that is then pumped around the heating circuit. The heated glycol is passed through a stainless steel heat exchanger.
  • Cooling system
    • 2 x10,5 kW R22 cooling compressor circulates refrigerant through a plate heat exchanger cooling a glycol mixture.
  • Heat from the compressors is removed from the system by a shell and tube refrigerant condenser using ships supply sea water.
  • An inlet water regulator for ship water supply pressure variances.
  • Chilled glycol mixture is circulated via a centrifugal pump and pumped through a stainless steel dehumidification and cooling heat exchanger.
  • Heliox gas is passed through the dehumidification heat exchanger and then directly afterwards through a centrifugal water separator.
  • Electrical system
    • Main electrical supply power requirement - either 380VAC, 3 phase, 50Hz, or 440VAC, 3 phase, 60 Hz - 40 Amps
    • Control circuit electrical supply power requirement - 220/240VAC, 50 Hz,16 Amps
  • Approximate weight = 800kg
  • Dimensions:
    • Length = 1100mm
    • Width = 910mm
    • Height = 1360mm

Back to top of page.


 

ECU Series Chamber Master Control Units

Air Diving - Chilled Fluid Environmental Control Master UnitTitle: Air Diving - Chilled Fluid Environmental Control Master Unit
Model No: ECU 50

Description:

  • Complete stainless steel frame construction.
  • Open design for ease of access and maintenance.
  • Manual condensate valves provided for draining of condensate.
  • All refrigeration piping lagged and protected.
  • Cooling System (7.5 kW, 24000 BTU)
  • Heat from the compressors is removed from the system by a shell and tube refrigerant condenser using ships supply sea-water
  • Physical Characteristics:
    • Length: 1,000mm
    • Width: 695mm
    • Height: 1,120mm
    • Weight: Approx 310 kg
  • Main Electrical Supply Power Requirement:-
    440 VAC, 3-Phase, 60 Hz – 20 Amps

Back to top of page.


 

HRC Water Cooled - Chilled Fluid Environmental Control Master UnitTitle: HRC Water Cooled - Chilled Fluid Environmental Control Master Unit
Model No: ECU 100

Description:

  • Complete stainless steel frame construction.
  • Open design for ease of access and maintenance.
  • Manual condensate valves provided for draining of condensate.
  • All refrigeration piping lagged and protected.
  • Heating System (12 kW)
  • Cooling System (10,5 kW, 36,000 BTU)
  • Physical Characteristics:
    • Length: 1,000mm
    • Width: 950mm
    • Height: 950mm
    • Weight: Approx 450 kg
  • Main Electrical Supply Power Requirement:-
    440 VAC, 3-Phase, 60 Hz – 20 Amps

Back to top of page.


 

HRC Air Cooled - Chilled Fluid Environmental Control Master UnitTitle: HRC Air Cooled - Chilled Fluid Environmental Control Master Unit
Model No: ECU 101

Description:

  • Complete stainless steel frame construction.
  • Open design for ease of access and maintenance.
  • Manual condensate valves provided for draining of condensate.
  • All refrigeration piping lagged and protected.
  • Heating System (12 kW)
  • Cooling System (8,5 kW, 28,000 BTU)
  • Physical Characteristics:
    • Length: 1,000mm
    • Width: 950mm
    • Height: 950mm
    • Weight: Approx 350 kg
  • Main Electrical Supply Power Requirement:-
    440 VAC, 3-Phase, 60 Hz – 20 Amps

Back to top of page.


 

SAT System - Chilled Fluid Environmental Control Master UnitTitle: SAT System - Chilled Fluid Environmental Control Master Unit
Model No: ECU 200

Description:

  • Complete stainless steel frame construction.
  • Open design for ease of access and maintenance.
  • Manual condensate valves provided for draining of condensate.
  • All refrigeration piping lagged and protected.
  • Heating & Cooling System (10,5 kW, 36,000 BTU)
  • Dehumidification System (10,5kW, 36,000 BTU)
  • Physical Characteristics:
    • Length: 1,000mm
    • Width: 950mm
    • Height: 950mm
    • Weight: Approx 420 kg
  • Main Electrical Supply Power Requirement:-
    440 VAC, 3-Phase, 60 Hz – 20 Amps

Back to top of page.


 

ICU - Heating & Cooling

Internal Chamber Environmental Control Unit - Heating and CoolingTitle: Internal Chamber Environmental Control Unit - Heating and Cooling
Model No: ICU

Description:

  • Stainless steel construction
  • Noise levels below 75 db
  • Drip tray with connection to bilge drain system
  • Designed for dual heating and cooling, with separate inlets for both fluids
  • Easily maintainable


Back to top of page.